KELLER Diamant
Kronaustrasse 5/7, 8404 Winterthur, Switzerland
Project Data
IPV System Data
Information and data provided by: Zurich Soft Robotics GmbH
Introduction
KELLER Diamant is the new manufacturing and assembly headquarters of KELLER Pressure AG in Winterthur, designed by Strut Architekten. Solskin is integrated on the south-facing glass façade as a dynamic secondary PV façade of about 1,250 m², positioned in front of the 90 m long building façade. The system combines photovoltaic production, adaptive shading, daylight control and architectural expression. It includes roughly 3,488 movable PV modules and is Solskin’s largest project to date.
Project approach
KELLER Diamant was conceived as a new industrial and workplace development that brings modern production facilities together with a comfortable, future-oriented working environment. From an early stage, the architectural and energy concept addressed the need for reliable indoor conditions, renewable energy generation and a building identity that reflects KELLER’s values of precision and innovation.
The South-facing glass façade was a key consideration, requiring effective solar protection alongside access to daylight and outward views. Integrating Solskin as an adaptive second skin brought shading, photovoltaic electricity generation and architectural expression into one façade system. Its movable modules regulate solar heat gains and daylight, helping to reduce glare and cooling demand while supporting comfort in the production and office spaces. The changing façade also gives the building a distinctive appearance, making environmental performance an integral part of its architecture.
Aesthetic integration
The PV modules are intentionally visible and form a dynamic façade layer. Instead of treating PV as a technical add-on, the project uses the movement, rhythm and depth of the Solskin modules as part of the building identity. The thick white frames are used as a deliberate design feature, while the 70 cm distance from the glass façade creates depth, transparency and a changing play of light and shadow. The result is a façade that communicates technological innovation while maintaining visual openness for the workplace behind it.
Technology integration
Solskin functions as a constructive secondary façade in front of the main glass façade. The system consists of 40 prefabricated Solskin units, each approximately 8.4 m × 3.7 m, carrying 3,488 small monocrystalline PV modules. The modules are mounted on a lightweight rod-and-support structure and are individually movable through Solskin’s soft-robotic actuation system. Besides producing electricity, the system provides adaptive solar shading, reduces solar gains, improves thermal and visual comfort, supports daylight control and contributes to reduced cooling demand.
Wiring and system interfaces are organized through the Solskin system architecture: PV DC feed-in via junction/communication lines, compressed-air supply for actuation, and control through the Solskin Hub. The Hub includes compressed-air treatment and the main control server for monitoring and AI-based operation.
Energy integration
The façade contributes through both on-site PV electricity generation and cooling-demand reduction by adaptive shading. For KELLER Diamant, the reported annual energy impact is about 140 MWh, combining electrical production and cooling-related energy savings. The adaptive tracking of the modules increases PV yield compared with static façade PV, while shading reduces solar gains on the south side and supports the building’s Minergie-oriented performance target.
Decision making
The decision to integrate Solskin was driven by KELLER Pressure AG’s vision for a technologically advanced, sustainable production and workplace building. The PV façade was selected because it could satisfy several requirements within one building element: architectural distinctiveness, on-site electricity production, solar-gain reduction, user comfort and corporate identity. The main challenge was the complexity of combining architecture, PV, shading, control, installation and maintenance into one integrated system; this was addressed through prefabricated façade units, system engineering, mock-ups and coordinated installation planning.
Lessons learnt
KELLER Diamant shows that IPV can become more than an energy system: it can act as a visible architectural and environmental control layer. A key lesson is that dynamic BIPV/APV should be involved early in the design process, because geometry, façade distance, mounting, maintenance access, wiring, inverter placement, compressed-air supply and control interfaces all influence the architectural result. The project also demonstrates the value of prefabrication: the large units reduced installation complexity, with each unit designed for rapid on-site installation. Future projects should continue to clarify technical-room needs, façade-cleaning access, electrical cabling and maintenance responsibilities early, as these details strongly affect cost, coordination and long-term operation.