Mississippi

Lungomare Cristoforo Colombo, Gabicce Mare (PU), Italy

Function
Multifunctional
IPV Architectural elements
Canopy
PV Integration Year
between 2021 and 2025
Source
BIPV meets History project

Project Data

Project type
Renovation
Heritage constraint
Conservation area
Building construction technique
Modern movement
PV integration year
2022

IPV System Data

Module technology
Module dimensions (mm)
1,646 x 1,140
System power (kWp)
13.2
System area (m²)
61.69
Modules orientation
South
Modules tilt [°]
8
Annual electricity production (kWh)
15,245
Coverage of electric consumption [%]
73

IPV System Costs

Total cost (€)
24,564
€/m²
398
€/kWp
1,861

Information and data provided by: Arch. Michele Bonini

Introduction

The Mississippi structure is suitable to be used for purposes of public interest and its enormous potential in this sense has been shared, recognized and confirmed in the 2014 international competition of ideas for the redevelopment of the Gabicce Mare waterfront, which saw the Mississippi as an essential constant in the process of transformation and enhancement of the entire city waterfront, constituting for everyone the real “attractor” of the urban promenade by the sea. Believing in the strong representative connotation and potential of the building as a vehicle for the promotion of a stretch of the Marche maritime coast, the Municipality has planned the intervention of static, energetic and functional recovery of it, which was also necessary for the safety and protection of the public security of the users of the beach. Within the intervention, a closing element above the building was built, curvilinear in shape, functional to the integration of a photovoltaic system, which constitute one of the characterizing elements of the energy efficiency of the new nZEB structure (nearly Zero Energy Building).

Project approach

The architectural design approach was to create a new volume, designed on the existing “colonnaded” grid, essential in its lines and figurative apparatus and represented through organic forms consistent with the semantic portrait of a building on the sea. The result is overall adequate to the place and to the extraordinary natural scenery with which the stilt structure is compared.

Aesthetic integration

The photovoltaic modules are mostly hidden from the main views.

Technology integration

The photovoltaic system is a shading structure. The modules (Viessmann Vitovolt 300 M4oo WG) are fixed through brackets bolted to the galvanized steel supporting roof system. The cables housed in visible PVC pipes.

Energy integration

The photovoltaic system supplies the summer-winter air conditioning, DHW production, lighting, transport (freight elevator/elevator). It allowed to reach the nZEB level (Nearly Zero Energy Building).

Decision making

The photovoltaic technology was introduced in the refurbishment project with the aim to abandon the fossil fuel sources (gas) and creating a new nZEB (nearly Zero Energy Building) energy self-sufficient.

Architectural Elements involved

Canopy
01

Stakeholders involved

Viessmann Srl
IPV producer
Contact us

Get expert support to design, evaluate or validate your IPV projects

Contact us now